Water pipeline and sewer take-off online
Drop the DXF of your longitudinal profiles (Covadis, Mensura…) or paste the levels from Excel: the tool computes the pipe length, the excavation by depth band, the pipe bedding, the surround, the backfill, the disposal, the manholes, air valves and washouts, then the bill of quantities to export to Excel. Free, nothing to install, nothing is sent.
4. Additional items (optional)
Take-off
What the tool computes
- Pipe length per section and in total, horizontal (like the chainages) and along the slope.
- Trench excavation, classified by depth band (≤ 1.50 m, 1.50 to 2.50 m, 2.50 to 3.50 m, over 3.50 m, editable).
- Bedding and surround in sand, compacted backfill and disposal of surplus excavated material with bulking.
- Warning mesh for water supply; manholes by depth for sewers.
- Fittings and structures: air valves, washouts, valves, standpipes, counted from the profile.
- Bill of quantities ready for pricing, and an Excel file with formulas that opens on the pipe detail per sheet (diameter, partial and cumulative distances, depth, earthworks, bedding, air valves, washouts and other fittings, levels, summary per Ø), then the bill of quantities, the progress measurement and the assumptions.
Importing a DXF of longitudinal profiles
In Covadis or AutoCAD, save the drawing as DXF and drop it in the import area. The tool looks for the profile tables: the rows Cote TN (existing ground level), Cote projet (design level, or invert), Distances cumulées (cumulative) or partielles (partial) and the node numbers. It also picks up the air valves, washouts and valves written above the profile, ignoring the legend.
Each profile found is listed with its length and a check “sum of partial distances = cumulative”. Tick those to keep: a complete profile that duplicates the profiles cut per sheet is unticked automatically. Ground points without a design level are kept to follow the ground, and the design level is interpolated there.
Entering or pasting the levels
Without a DXF, paste your table from Excel: one row per point, with the node name, the cumulative distance (or paste the partial distances in their column), the ground level, the design level and, if needed, the fitting. A cumulative distance that restarts from 0 begins a new profile: you can paste several pipelines one after the other, each with its diameter (Ø column). This is also the method for a PDF or scanned profile.
Example: HDPE Ø 110 water pipeline
Eight nodes over 326.30 m, a trench 0.60 m wide and about 1.30 m deep (the design level being the trench bottom), 0.10 m of bedding and 0.20 m of surround: the excavation is 256.00 m³, the sand (bedding and surround) 77.17 m³, the backfill 175.73 m³, and there is one air valve, one washout and one valve. Tap Example to see the detail, then Wastewater for a PVC Ø 315 sewer with its manholes.
Frequently asked questions
How do I calculate the excavation volume of a trench?
For each section between two points of the profile: volume = length × trench width × average depth. The depth at a point is ground level − design level, plus the bedding thickness if the design level is the pipe invert. All the sections are then added up, classified by depth band.
What trench width should I use for a pipe?
The common rule is the outside diameter plus 0.40 m (20 cm on each side), with a minimum of 0.60 m to be able to work. For Ø 110 this gives 0.60 m, for Ø 315 about 0.75 m. Your specification or standards may require other values: the width can be edited.
How do I calculate the sand bedding and surround?
Bedding = length × width × thickness (often 0.10 m for water supply, 0.15 m for sewers). Surround = length × (width × (Ø + height above the pipe) − π Ø² / 4): the volume occupied by the pipe is deducted.
How is the backfill calculated?
Backfill = excavation − bedding − surround − pipe volume. The difference between excavation and backfill, multiplied by the bulking factor, gives the surplus material to dispose of.
Can I import a longitudinal profile from Covadis?
Yes: save the drawing as DXF and drop it. The tool reads the profile table (ground level, design level or invert, partial or cumulative distances, node numbers) and the air valves, washouts and valves drawn above it. Several profiles in the same DXF are recognised and loaded one after the other.
What if I have a DWG or a PDF?
The DWG must first be saved as DXF (AutoCAD, Covadis or the free ODA converter). For a PDF, and above all a scanned PDF, copy or paste the profile levels into the table: node, chainage, ground level, design level. The calculation is the same.
What is a bill of quantities?
The priced list of contract items (pipe, excavation, sand, backfill, manholes, air valves…) with their quantity, unit price and amount. The tool prepares it from the take-off; you only have to enter your prices.